Description
This is a 2 Ton 208/220 Volts 1-Phase Direct Factory Replacement Copeland Scroll Compressor. The Copeland Model # is ZR25K5E-PFV-800. It is rated at 25,000 BTU.In some instances, small piping changes may be required. Thanks for looking and good luck!
This compressor is designed to replace old Rheem/Ruud/Weather King/Corsaire/Copeland numbers: 55-23140-10 55-23140-10S
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 25300
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 40/370
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 15.0
Max. Continuous Current (A): 21.0
Locked Rotor Current (A): 68.0
Crankcase Heater Included?: No
Crankcase Heater Part Number: 44-17402-44
Suction Line Location: 2
Suction Line Height (in.): 10-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 3/4
Discharge Line Location: 3
Discharge Line Height (in.): 14-3/16
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 15-5/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To install a Compressor PROPERLY you need to have AND use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. All Sales are Final! There are NO WARRANTIES! Compressors Should be installed by a qualified Heating Air Conditioning Tech.
This compressor is designed to replace old Rheem/Ruud/Weather King/Corsaire/Copeland numbers: 55-23140-10 55-23140-10S
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 25300
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 40/370
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 15.0
Max. Continuous Current (A): 21.0
Locked Rotor Current (A): 68.0
Crankcase Heater Included?: No
Crankcase Heater Part Number: 44-17402-44
Suction Line Location: 2
Suction Line Height (in.): 10-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 3/4
Discharge Line Location: 3
Discharge Line Height (in.): 14-3/16
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 15-5/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To install a Compressor PROPERLY you need to have AND use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. All Sales are Final! There are NO WARRANTIES! Compressors Should be installed by a qualified Heating Air Conditioning Tech.
Function:
Compressors compress refrigerants (freon) from a gas state into a liquid state and then pump it through the freon lines.
Replaces Old Part #s:
Repair Difficulty Level:
Partial List of Units that Use This Item:
Hit Ctrl+F and enter your model number for a quick search!