Description
This is a 4 Ton 208/220 Volts 1-Phase Direct Factory Replacement Copeland Scroll Compressor. the Copeland Model # is ZR48K5E-PFV-800. It is rated at 48,200 BTU and is designed to replace old Rheem/Ruud/Weather King/Corsaire model # 55-21737-37, 55-21737-37S, 55-23139-18. Thanks for looking and good luck!
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 48200
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 60/440
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 24.3
Max. Continuous Current (A): 34.0
Locked Rotor Current (A): 137.0
Crankcase Heater Included?: No
Suction Line Location: 2
Suction Line Height (in.): 11-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 7/8
Discharge Line Location: 3
Discharge Line Height (in.): 15-3/8
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 16-7/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To install a Compressor PROPERLY you need to have AND use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. All Sales are Final! There are NO WARRANTIES! Compressors Should be installed by a qualified Heating Air Conditioning Tech.
TECHNICAL SPECIFICATIONS
Capacity (BTU/HR): 48200
Type: Scroll
Refrigerant: R-22
Input Voltage (V): 208
Input Voltage (V): 230
No. of Phases: 1
Freq. (Hz.): 50
Freq. (Hz.): 60
Run Capacitor (uF/V): 60/440
Start Relay P/N: 42-25105-01
Start Capacitor (uF/V): 88-106/330
Start Capacitor Part Number: 43-17075-04
Rated Load Current (A): 24.3
Max. Continuous Current (A): 34.0
Locked Rotor Current (A): 137.0
Crankcase Heater Included?: No
Suction Line Location: 2
Suction Line Height (in.): 11-1/8
Suction Line Configuration: Stub Out
Suction Line Size (in.): 7/8
Discharge Line Location: 3
Discharge Line Height (in.): 15-3/8
Discharge Line Configuration: Stub Out
Discharge Line Size (in.): 1/2
Overall Compressor Height (in.): 16-7/16
Mounting Base Dimensions (in. x in.): 7-1/2 x 7-1/2
To install a Compressor PROPERLY you need to have AND use the proper equipment and use proper installation technique. If you are not familiar with these techniques or you do not have the proper equipment then you SHOULD have a qualified HVAC tech to install your new compressor. All Sales are Final! There are NO WARRANTIES! Compressors Should be installed by a qualified Heating Air Conditioning Tech.
Function:
Compressors compress refrigerants (freon) from a gas state into a liquid state and then pump it through the freon lines.
Replaces Old Part #s:
Repair Difficulty Level:
Partial List of Units that Use This Item:
Hit Ctrl+F and enter your model number for a quick search!